Transformer 12kV swtichgear manufacturers take you to understand the basic composition of switchgear

Transformer 12kV swtichgear manufacturers take you to understand the basic composition of switchgear

  • Categories:LATEST NEWS
  • Author:
  • Origin:
  • Time of issue:2023-03-17 10:30
  • Views:

(Summary description)The manufacturer of transformer 12kV swtichgear tells you that the switchgear is composed of various functional circuits (including grounding switchgear and load switchgear). The metal shell and the circuit are sealed with bus bars, and the shell is welded with 3mm cold-rolled steel plate (or stainless steel plate).

Transformer 12kV swtichgear manufacturers take you to understand the basic composition of switchgear

(Summary description)The manufacturer of transformer 12kV swtichgear tells you that the switchgear is composed of various functional circuits (including grounding switchgear and load switchgear). The metal shell and the circuit are sealed with bus bars, and the shell is welded with 3mm cold-rolled steel plate (or stainless steel plate).

  • Categories:LATEST NEWS
  • Author:
  • Origin:
  • Time of issue:2023-03-17 10:30
  • Views:
Information

The manufacturer of transformer 12kV swtichgear tells you that the switchgear is composed of various functional circuits (including grounding switchgear and load switchgear). The metal shell and the circuit are sealed with bus bars, and the shell is welded with 3mm cold-rolled steel plate (or stainless steel plate). Each functional circuit includes a load switch and a ground switch. The load switch consists of a moving contact system that moves vertically and a static contact at the bottom. When the switch is closed, the moving contact moves down and the load switch opens.

good price and quality transformer 12kV swtichgear components
The grounding switch consists of movable blades and fixed blades. When the spring moves, the grounding switch opens quickly. The transformer 12kV swtichgear manufacturer tells you that there are four rectangular assembly process holes on the top and back of the switch chamber. There is an observation window on the front of the ring network cabinet. You can see the "open" and "closed" positions of the grounding switch. An explosion-proof device is installed on the back of the ring body.
The load switch adopts the compressed air internal blowing structure. The arc extinguishing ability is strong, without affecting the phase-to-phase and ground insulation, and the moving and static contacts are equipped with arc contacts, which greatly increases the number of breaking times.
The transformer 12kV swtichgear manufacturer tells you that the next step is the fuse room, and the fuse and the load switch room constitute the transformer protection circuit. The high-voltage current-limiting fuse is installed in an epoxy resin casting insulating shell. After the fuse is blown, the striker pops up and the load switch is disconnected.
The control room is located at the front of the annulus. In each functional circuit, the load switch is equipped with a human (or electric) stored energy spring actuation mechanism. The transformer 12kV swtichgear manufacturer tells you that the grounding switch is equipped with a human body energy storage spring actuation mechanism, and there are opening and closing drive holes on the panel, which are used for the closing of the load switch, the manual opening knob and the grounding switch. Equipped with load switch opening and closing position indicator light and electric opening and closing button, analog line, switch status display board and locking position, the operation of load switch and grounding switch has interlocking to prevent misoperation.

Keyword:

RELATED NEWS
2023-04-07

Application of Transformer 2000A swtich panel in energy field

In the field of energy, transformers have always played an important role. As one of the core equipment in the power transmission and distribution system, the transformer can step down high-voltage electric energy into low-voltage electric energy suitable for consumption by families, factories, and enterprises. In terms of transformer switch control.
See more information
2023-03-28

Transformer 2000A swtich panel manufacturers take you to understand the classification of switch panels by switch connection

What are the classifications of switch panels? Transformer 2000A swtich panel manufacturers tell you that switch panels are classified according to different classification methods. The common classification methods of switch panels include switch connection mode, panel, disconnection of contacts, starting method, installation, protection level of harmful water ingress, etc.
See more information

CONTACT US

Add:No. 972, Antai 3rd Road, Xishan Eco & Tech Development Zone, Wuxi,Jiangsu , China. 214106

language
中国
韩国
韩国
韩国
韩国
韩国

BAIFApower.com BAIFA© 2019 All Rights Reserved.  www.300.cn wuxi   苏ICP备19027668号-1    苏ICP备19027668号-2   Privacy Policy

ONLINE

Username used for comment:
客户留言
Description:
验证码