Baifa Common Control Panel Module | ||||||||||
Specific Description:one Genset one panel, one panel mounted on each genset, which is convenient for independent operation, AMF automatic main fault operation,synchronous operation, etc. | ||||||||||
FUNCTION | PARALLELED GENSET | PARALLELED GENSET | PARALLELED GENSET CONTROLLER | PARALLELED GENSET CONTROLLER | PARALLELED GENSET CONTROLLER | |||||
MODELS | BaiFa BF91 | ![]() | DEEPSEA DSE8610MKII | ![]() | DEIF AGC150 | ![]() | COMAP IG200 | ![]() | COMAP IG-NTC GC | ![]() |
Functional comparison | —include USB & RS485 ports | —include USB & RS485 ports | —include USB & RS485 ports | —include USB & RS485 ports | —include USB & RS485 ports | |||||
—include RJ45 Ethernet | —include RJ45 Ethernet | —include RJ45 Ethernet | — | — | ||||||
—Support Extension | —Support Extension | —Support Extension | —Support Extension | —Support Extension | ||||||
—Cutout Dimension:214*160 (mm) | —Cutout Dimension:220*160 (mm) | —Cutout Dimension:220*160 (mm) | —Cutout Dimension:187*132 (mm) | —Cutout Dimension:172*112 (mm) | ||||||
— | —Configurable LEDs | — | — | — | ||||||
—5 configurable analogue/digital inputs (Support for 0 V to 10 V & 4-20 mA sensors) | —4 configurable analogue/digital inputs (Support for 0 V to 10 V & 4-20 mA sensors) | —4 configurable analogue/digital inputs (Support for 0 V to 10 V & 4-20 mA sensors) | —4 configurable analogue/digital inputs | —4 configurable analogue/digital inputs (Support for 0 V to 10 V & 4-20 mA sensors) | ||||||
— — Internal PLC editor | —Manual and automatic fuel pump control — Internal PLC editor | — — Internal PLC editor | — — Internal PLC editor | — — Internal PLC editor | ||||||
—Configurable Stastus home pages screens | —Configurable Stastus home pages screens | —Configurable Stastus home pages screens | — | — | ||||||
— Illuminated LEDs & horn | — Illuminated LEDs & horn | — Illuminated LEDs | — Illuminated LEDs | — Illuminated LEDs | ||||||
—Silica-gel panel and keys | —Silica-gel panel and keys | —Acrylic screen and keys | —Acrylic screen and keys | —Acrylic screen and keys | ||||||
— | —Received Instrumentation | — | — | — | ||||||
—Ignore CAN alarm list | —Ignore CAN alarm list | — | —Ignore CAN alarm list | — | ||||||
—It supports setting parameter values and writing configuration files in any mode | —only partial set parameter values are supported, and the configuration file needs to be written in the shutdown state | —It supports setting parameter values and writing configuration files in any mode | —only parameter values can be set. The configuration file needs to be written in the shutdown state | —only parameter values can be set. The configuration file needs to be written in the shutdown state | ||||||
Extensin | —DIN16 Extensin Modules | —DSE124CAN/MSC Extensin | —CIO116 : 16 input Modules | —CM-4G-GPS 4G plug-in module | —InternetBridge-NT-4G Extensin Modules | |||||
—DOUT16 Extensin Modules | —DSE2130 input Extensin | —CIO208: 8 output Modules | —CM-Ethernet | —InternetBridge-NT Extensin Modules | ||||||
—AIN8 Extensin Modules | —DSE2131 input Extensin | —CIO308: 8 analogue extension | —EM-BIO8-EFCP 8 Extensin Modules | —EM-BIO8-EFCP 8I/O Extensin Modules | ||||||
— | —DSE127CAN/MSC Extensin | — | —Inteli AIN8 8 analogue extension | —Inteli AIN88 analogue extension | ||||||
— | —DSE128CAN/MSC Extensin | — | —Inteli AIN8TC 8 analogue extension | —Inteli AIN8TC 8 analogue extension | ||||||
— | —DSE2133 CAN/MSC Extensin | — | —Inteli IO8/8 8 I/O Extensin Module | —Inteli IO8/8 I/O Extensin Modules | ||||||
— | —DSE2152 CAN/MSC Extensin | — | —IGL-RA15 | —IV5 Color screen | ||||||
— | —DSE2157 CAN/MSC Extensin | — | — | —IV8 Color screen | ||||||
— | —DSE8004 10" Color scree | — | — | — |
Baifa Common Control Panel Module | ||||||||||||||
Specific Description:one Genset one panel, one panel mounted on each genset, which is convenient for independent operation, AMF automatic main fault operation, operation, etc. | ||||||||||||||
FUNCTION | SINGLE GENSET CONTROLLER | SINGLE GENSET CONTROLLER | SINGLE GENSET CONTROLLER | SINGLE GENSET CONTROLLER | SINGLE GENSET CONTROLLER | SINGLE GENSET CONTROLLER | SINGLE GENSET CONTROLLER | |||||||
MODELS | Baifa BF61 | ![]() | Baifa BF62 | ![]() | DEEPSEA DSE4520/4620 | ![]() | DEEPSEA DSE6120MKIII | ![]() | DEEPSEA DSE7320MKII | ![]() | COMAP IL4-MRS16 | ![]() | COMAP IL4-AMF25 | ![]() |
Functional comparison | —include USB ports | —include USB ports | —include USB ports | —include USB ports | —include USB ports | —include USB ports | —include USB ports | |||||||
—include RS485 ports | —include RS485 ports | — | — | —include RS485 ports | —include RS485 ports | —include RS485 ports | ||||||||
—Flexible, extendable | —Flexible, extendable | — | —Flexible, extendable | —Flexible, extendable | —Flexible, extendable | —Flexible, extendable | ||||||||
—Cutout Dimension:186*141(mm) | —Cutout Dimension:186*141(mm) | —Cutout Dimension:118*92(mm) | —Cutout Dimension:184*137(mm) | —Cutout Dimension:220*160(mm) | —Cutout Dimension:187*132(mm) | —Cutout Dimension:187*132(mm) | ||||||||
— | — | — | —Configurable LEDs | —Configurable LEDs | — | — | ||||||||
—3 configurable analogue/digital inputs (Support for 0 V to 10 V & 4-20 mA sensors) | —3 configurable analogue/digital inputs (Support for 0 V to 10 V & 4- 20 mA sensors) | —3 configurable analogue/digital inputs(Support for 0 V to 10 V & 4- 20 mA sensors) | —4 configurable analogue/digital inputs (Support for 0 V to 10 V & 4- 20 mA sensors) | —6 configurable analogue/digital inputs (Support for 0 V to 10 V & 4- 20 mA sensors) | —4 configurable analogue/digital inputs —+5 V output reference for analog inputs | —4 configurable analogue/digital inputs —+5 V output reference for analog inputs | ||||||||
— | — | — | —Manual and automatic fuel pump control | —Manual and automatic fuel pump control | — | — | ||||||||
—Configurable Stastus home pages screens | —Configurable Stastus home pages screens | — | —Configurable Stastus home pages screens | —Configurable Stastus home pages screens | — | — | ||||||||
— Internal PLC editor | — Internal PLC editor | — Internal PLC editor | — Internal PLC editor | — Internal PLC editor | — Internal PLC editor | — Internal PLC editor | ||||||||
— Illuminated LEDs | — Illuminated LEDs | — Illuminated LEDs | — Illuminated LEDs | — Illuminated LEDs | — Illuminated LEDs | — Illuminated LEDs | ||||||||
—Silica-gel panel and keys | —Silica-gel panel and keys | —Acrylic screen and keys | —Acrylic screen and keys | —Silica-gel panel and keys | —Acrylic screen and keys | —Acrylic screen and keys | ||||||||
— | — | —Received Instrumentation | —Received Instrumentation | —Received Instrumentation | — | — | ||||||||
—Ignore CAN alarm list | —Ignore CAN alarm list | —Ignore CAN alarm list | —Ignore CAN alarm list | —Ignore CAN alarm list | —Ignore CAN alarm list | —Ignore CAN alarm list | ||||||||
— | —Support AMF | —Support AMF | —Support AMF | —Support AMF | — | —Support AMF | ||||||||
— optional 8 language interface | — optional 8 language interface | — | — optional 2language interface | — optional 3 language interface | — optional 3 language interface | — optional 3 language interface | ||||||||
—It supports setting parameter values and writing configuration files in any mode | —It supports setting parameter values and writing configuration files in any mode | —only partial set parameter values are supported, and the configuration file needs to be written in the shutdown state | —only partial set parameter values are supported, and the configuration file needs to be written in the shutdown state | —only partial set parameter values are supported, and the configuration file needs to be written in the shutdown state | —only parameter values can be set. The configuration file needs to be written in the shutdown state | —only parameter values can be set. The configuration file needs to be written in the shutdown state | ||||||||
—Support Remote Display | —Support Remote Display | — | — | —Support Remote Display | —Support Remote Display | —Support Remote Display | ||||||||
Extension | —AIN8 analogue extension | —AIN8 analogue extension | —DSE855 Ethernet | —DSE855 Ethernet | —DSE855 Ethernet | —CM-4G-GPS 4G plug-in module | —CM-4G-GPS 4G plug-in module | |||||||
—Low temperature version | —Low temperature version | —DSE857 RS485 Modbus | —DSE857 RS485 Modbus | —DSE857 RS485 Modbus | —CM-RS232-485 Modbus | —CM-RS232-485 Modbus | ||||||||
—Support 4G wireless | —Support 4G wireless | — | —DSE2131 input Modules | —DSE2131 input Modules | —CM-Ethernet | —CM-Ethernet | ||||||||
— | — | —DSE127CAN/MSC | —DSE127CAN/MSC | —EM-BIO8-EFCP 8 I/O extension | —EM-BIO8-EFCP 8 I/O extension | |||||||||
— | — | — | —DSE128CAN/MSC | —DSE128CAN/MSC | —Inteli AIN8 8 analogue extension | —Inteli AIN8 8 analogue extension | ||||||||
— | — | — | —DSE2133 input Modules | —DSE2133 input Modules | —Inteli AIN8TC 8 analogue extension | —Inteli AIN8TC 8 analogue extension | ||||||||
— | — | — | —DSE2152 output Modules | —DSE2152 output Modules | —Inteli IO8/8 8/8input/output Modules | —Inteli IO8/8 8/8input/output Modules | ||||||||
— | — | — | —DSE2157 output Modules | —DSE2157 output Modules | —IGL-RA15 15LED | —IGL-RA15 15LED | ||||||||
— | — | — | —DSE2548 LED Modules | —DSE2548 LED Modules | — | — |